Back to Basics: Failure Rates - FIT
Failures In Time or Failure UnIT
FIT is the number of failures per billion hours for a piece of equipment.
It is mentioned in both IEC 61508 and IEC 61511 standards as a preferred unit of measurement expressed by 109 hours.
Example: 5 FIT is expressed as 5 failures within 109 hours .
When you…
Read More...
- by Loren Stewart, CFSE
- Thursday, March 19, 2020
- Functional Safety
Back to Basics: Failure Rates - λ
The Greek symbol lambda, λ, represents failure rates in functional safety, usually expressed in the unit of measurement of FITS.
λ can be expressed as a total failure rate for a device (λT), or it can be broken down into more specific groupings:
- by Loren Stewart, CFSE
- Thursday, April 02, 2020
- Functional Safety
Back to Basics: Failure Rates - λD
The Greek symbol λD represents dangerous failure rates in functional safety, usually expressed in the unit of measurement of FITs, and can be determined through FMEDAs. (FITs (λ) are failures per billion hours, expressed by 10-9 hours).
λD is the number of dangerous failures per…
Read More...
- by Loren Stewart, CFSE
- Tuesday, June 30, 2020
- Functional Safety
Back to Basics: Failure Rates - λDD
The Greek symbol λDD is the detectable dangerous failure rate in functional safety expressed in the unit of measurement of FITs which can be determined through FMEDAs. (FITs (λ) are failures per billion hours, expressed by 10-9 hours).
λDD is the number of…
Read More...
- by Loren Stewart, CFSE
- Thursday, June 04, 2020
- Functional Safety
Back to Basics: Failure Rates - λDU
The Greek symbol λDU is the undetectable dangerous failure rate in functional safety expressed in the unit of measurement of FITs which can be determined through FMEDAs. (FITs (λ) are failures per billion hours, expressed by 10-9 hours).
λDU is the number of dangerous undetected failures…
Read More...
- by Loren Stewart, CFSE
- Tuesday, August 18, 2020
- Functional Safety
Back to Basics: Failure Rates - λS
The Greek symbol λS represents safe or spurious failure rates in functional safety expressed in the unit of measurement of FITs which can be determined through FMEDAs. (FITs (λ) are failures per billion hours, expressed by 10-9 hours).
λS is the number of safe…
Read More...
- by Iwan van Beurden, CFSE
- Wednesday, October 16, 2013
- Functional Safety
Why Does My Proof Test Coverage Change with Partial Stroke Testing?
I have run into this question a couple of times now and though the answer is somewhat straightforward, some customers have trouble wrapping their head around this without a clear example. So here we go…
First of all we need to keep in mind that the objective of a…